Ad Code

Alamat : Jl. H Kelik No.20B Kelapa Dua Kebon Jeruk Jakarta Barat 11550 Telp. 021.220.54159 Up Asep | WA : 0822.1729.4199 e-mail : atantan.margasetia@gmail.com

HACH 2100N Bench Laboratory Turbidity Meter

Hach 2100 Series Laboratory Turbidimeters are engineered to provide superior accuracy and sensitivity in any application. The 2100AN is equipped with a stable halogen-filled tungsten filament lamp to meet the reporting requirements of EPA Method 180.1. This model is ideal for testing higher ranges of turbidity up to 10, 000 NTU. Additional absorbance, transmittance, and color measurement modes make the 2100AN the most flexible of any Hach benchtop turbidimeter.
Ratio technology provides highly accurate results
Interchangeable color filters provide ultimate flexibility
Optional cell adapters for the 2100AN Turbidimeter allow measurement of smaller sample volumes
Built-in printer provides a record of calibration and measurement data
Air purge prevents condensation in the sample chamber of the 2100AN
Specification:
Absorbance: 0.001 Abs on lowest rangeAccuracy: ± 2 % of reading plus 0.01 NTU from 0 to 1000 NTU
± 5 % of reading from 1000 to 4000 NTU
± 10 % of reading from 4000 to 10, 000 NTUAir Purge: 0.1 scfm at 69 kPa , hose barb connection for 1/ 8 in tubing, maximum 138 kPa. Dry nitrogen or instrument-grade air.Compliance certifications: UL/ CSADimensions Metric ( H x W X D) : 156 mm x 400 mm x 305 mmIncludes: Instrument, sample cells, StablCal calibration standards, silicone oil, oiling cloth, dust cover, manual, power cord with NA plug, EPA filter, 455 nm color filter, printer paperManual Languages: English, Spanish, GermanMax. operating humidity: 90Measurement Modes: NTU, Nephelo, EBC, ABS, % T, Color, ASCMeasurement range: Ratio On: Manual 0 to 10000 ; Auto 0 – 10, 000 auto decimal; Ratio Off: 0 – 40.0Measuring Range: 0 to 10000 NTUOperating Temperature Range: 0 to 40 ° CPrinter: Built-in ( thermal, 58 mm, up to 28 column) Regulatory: USEPA method 180.1Repeatability: ± 1 % of reading or ± 0.01 NTU, whichever is greaterResolution: 0.001 NTU ( FNU) on lowest rangeResponse Time: 6.8 s with signal averaging off
14 s with signal averaging onSample Cell Compatibility: 25 mm round; 12, 13, 16, and 19 mm round with optional adapter kitSample Volume: 20 mL with 25 mm sample cell
2.5 mL with 12 mm
3.5 mL with 13 mml
5 mL with 16 mml
7 mL with 19 mmSerial input interface: RS232 serial interface ( bidirectional) Storage Conditions: -40 ° C to 60 ° CUser Interface Languages: EnglishUser Programs: 2Warranty: 2 yearsWeight: 8.31 lbs. ( 3.77 kg) Width: 40 cm